The instant_rate mode existed in the enum but had no normalizer, so normalizing a power/flow sensor threw NotSupportedException. InstantRateNormalizer integrates the rate over time (trapezoidal, attributed to each interval's end reading); a per-hour rate in the meter's unit yields the consumption unit (kW->kWh, L/h->L). Registered in the engine; meter editor shows a mode hint. +4 Core tests.
Claude-Session: https://claude.ai/code/session_01Kib2MniVFbD95fkgLgBBnB
Three requested phases.
1) Admin section (SDD §8.7) — MudBlazor inline-dialog CRUD, consistent pattern,
delete guards, snackbar feedback, shared Confirm helper:
- Energy types: create/edit/delete (blocks delete when meters reference it).
- Meters: create/edit/delete; recomputes consumption when mode/baseline
changes (NormalizationService over a fresh factory context, in a tx);
delete cascades data (consumption+readings are Restrict → removed first).
- A meter's ingest sources: manage on the meter-detail Sources tab
(add/edit/delete MQTT/Tasmota/HA sources with typed config).
- Tariffs: full CRUD (scope/component/value/validity).
- Cost categories: CRUD + member management (meter or energy-type members).
- Connectors: ingestion_endpoint CRUD (MQTT broker + Home Assistant);
secrets referenced by env-var name only, never stored.
- Settings: read-only effective-config view (settings are env-driven and
reproducible, so an editable form would change nothing — kept honest).
PV role is now editable on meters (MeterMeta.SetRole can clear a role).
2) Read Home Assistant — extracted a shared public HaEndpointConfig (was a
private record in the worker), added HaConnectionTester (powers the connector
"Test connection": checks base URL + env-resolved token, optionally reads one
entity). Configuring an HA connector + an HA source on a meter drives the
existing REST-poll worker end to end. (WebSocket push stays a future
optimization; REST poll already reads HA.)
3) Wiring/placeholder audit — swept every OnClick/Href: all handlers are real,
all internal links resolve to real routes, no TODO/stub/placeholder code.
Fixed one genuine gap: MainLayout had no drawer toggle, so the nav was
unreachable on narrow screens — added a hamburger button.
Tests: +6 (MeterMeta.SetRole role-removal; HaConnectionTester fail-closed
guard branches with a throwing HttpClientFactory proving no network on bad
config); render test now covers all admin routes. 69 Core + 45 Integration =
114 green. Live-verified in Docker: all admin pages 200, drawer toggle present,
Settings shows real effective config.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
Complete the SDD §8 dashboard views that were deferred at the M5 boundary,
and fix a shipping bug that left the Docker demo empty.
Bug: "Load reference data" created meters/tank/tariffs but imported zero
readings in Docker. Root cause: sampledata/ was excluded by .dockerignore and
never copied into the build stage, so the App csproj's linked Content glob
resolved to nothing at publish time; ReferenceDataImporter then silently
skipped the missing CSVs after already writing its marker meter, leaving the
DB permanently "loaded" but empty.
- .dockerignore: stop excluding sampledata/
- Dockerfile: COPY sampledata/ into the build stage
- ReferenceDataImporter: fail-fast (validate CSVs exist before the marker
meter) and throw instead of silently skipping a missing file
- Program.cs + MeterVaultOptions: opt-in MeterVault__SeedReferenceData
(compose METERVAULT_SEED=true) for a one-command populated demo
New SDD §8 panels (read models in Infrastructure/Dashboard, Blazor pages):
- §8.4 Solar/PV (/solar): generation from GenerationCounter meters;
self-consumption / autarky % / self-consumption % / savings derived from
meters tagged total_load & grid_import via Meter.Meta role config
(MeterRoles/MeterMeta) — nothing hardcoded by name.
- §8.5 Oil/consumable (/consumables): tank level (cm→L calibrated), fill
gauge, deliveries log, burner runtime, effective L/h (fixed/empirical),
forecast-to-empty, tariff cost, monthly series.
- §8.6 Meter detail (/meters/{id}): raw readings, normalized consumption,
source status, tariff timeline, events, measured-vs-estimated markers.
- Reusable SeriesChart component; nav links; Meters list rows link to detail.
Tests: MeterMetaTests (Core, +10); DashboardRenderTests extended to assert the
three panel services compute real figures and the new routes render (108 total,
all green). Live-verified in Docker: seed imports 302 readings / 347 consumption
rows; panels render (generation 16,481 kWh, oil 3,967 L) cross-checking the DB.
Claude-Session: https://claude.ai/code/session_01Lz2RqAsnQhetqWNoCDfexK
- German-dialect scalar parsers in Core (GermanNumber/Money/Date, ValueCell):
decimal comma, thousands dot, unit suffixes, € currency, both date shapes.
- Declarative MappingProfile + RowClassifier (skip summary/blank/all-zero rows) +
CsvImporter (CsvHelper) staging readings/events/manual-costs, with auto swap
detection on register decreases and month-end anchoring for interleaved oil dates.
- Four built-in ReferenceProfiles (Strom/Wasser/Heizöl/Kosten).
- ImportService: commit as revertible import_batch + wholesale consumption recompute
per affected meter (NormalizationService/MeterConfigFactory), revert by batch.
- Reconciliation tests: all 4 CSVs match the sheet's own columns within tolerance
(electricity 5 meters + Netz Einsparung, water swap→12, oil tank incl. deliveries +
burner hours, cost category totals). Commit/revert round-trip verified on Timescale.
69 tests green (53 Core + 16 integration).
Known follow-up (polish): historical imports can contend with the 30-day compression
policy's background job; tests pause it. Consider retry-on-deadlock or deferred
compression for large historical imports in production.
Claude-Session: https://claude.ai/code/session_01WujdMtMJPbxDpDnMeK22rr