Reference-only secrets (SDD §6.4) meant adding a connector required editing a file on the server and restarting the service. In practice that leads to the token being pasted into the env-var *name* field, which fails with "environment variable '<token>' is not set" and gives no hint what went wrong. Add a second storage form, chosen per connector: type the secret in and it is encrypted via ASP.NET Core data protection before it is stored. The env-var reference stays as an equal alternative — this widens the choice rather than replacing it. Exactly one form survives a save, so a stale secret cannot linger and silently win; EndpointSecret.Resolve is the single resolution path. The guarantee that matters is preserved: no plaintext in the database, so pg_dump and JSON exports carry nothing usable. The trust boundary is stated plainly in §6.4 — the key ring is on disk, so this protects against leaked database content, not an attacker who already has the host, which is the same boundary an env var has. Details worth noting: - Key ring defaults to /var/lib/metervault/keys, outside the app directory, because the LXC updater republishes /opt/metervault on every update. Docker gets a named volume. Overridable via MeterVault__DataProtectionKeyPath. - Undecryptable ciphertext (key ring lost) falls back rather than throwing: an ingestion worker on a timer should degrade, not crash. - The stored secret is never sent to the browser; a blank field means "unchanged", not "cleared". - MQTT usernames are stored as-is — §6.4 covers tokens and passwords, and encrypting a username would only blank the field on every edit. - ExportService drops *_enc values: bound to the originating key ring, so useless where an export would be restored. Expect to re-enter after a restore. - HaConnectionTester now takes a resolved token, so the admin UI can test a token that has been typed but not yet saved. SDD §6.4 and §9 updated to describe both forms rather than contradict the code. Claude-Session: https://claude.ai/code/session_01V6joyergfvVLFEizH1hJLd
12 KiB
CLAUDE.md
This file provides guidance to Claude Code (claude.ai/code) when working with code in this repository.
What this repo is
MeterVault is a self-hosted, local-first energy & utility metering platform: it ingests meter data from Home Assistant, Tasmota and MQTT on a schedule, stores every reading timestamped and immutable, normalizes it into consumption, and turns it into cost dashboards. Energy types (electricity, water, heating oil, gas, …) and meters are user-defined, never hardcoded.
Status: implemented (M0–M7) + SDD §8 panels. The full solution is built and green — five projects, ~108 tests, working Docker deploy. docs/SDD.md remains the design reference; the milestone map (§12) matches the git history (M0…M7 commits). The dedicated PV/Solar (/solar), Oil/consumable (/consumables) and meter-detail (/meters/{id}) views (SDD §8.4–§8.6) are implemented as read models in Infrastructure/Dashboard (SolarService, ConsumableService, MeterDetailService) — PV meters are found by Mode == GenerationCounter and grid/load meters by a role tag in Meter.Meta (MeterRoles/MeterMeta), so nothing is hardcoded by name. Admin write-CRUD (SDD §8.7) is implemented as MudBlazor inline-dialog pages: energy types, meters (+ recompute on mode/baseline change), a meter's ingest sources (meter-detail Sources tab), tariffs, cost categories + members, and connectors (ingestion_endpoint, secrets by env-var reference only). /admin/settings is a read-only effective-config view (settings are env-driven and reproducible, not DB-stored). Home Assistant reading is configured here: an HA connector (BaseUrl + TokenEnv) + an HA source (entity id) drives HomeAssistantWorker's REST poll, or — with the connector's WebSocket push toggle (HaEndpointConfig.UseWebSocket) — HomeAssistantWebSocketWorker holds a persistent state_changed subscription and ingests in real time (the poll worker skips WS endpoints, so each is served once; HaWebSocketProtocol is the pure, unit-tested handshake/parse logic). HaConnectionTester powers the connector "Test connection" button. Meter topology & flow: MeterLink (a directed from→to edge; a downstream meter is a subsection of an upstream one, multi-parent allowed) drives a per-energy-type page /energy/{id} with a hand-rolled SVG Sankey (SankeyChart.razor, since ApexCharts has no Sankey type) computed by FlowService (link value = downstream consumption, split proportionally across multiple parents; unaccounted remainder → an "Other" node). Upstream meters are wired cycle-safely in the meter editor; the nav lists a link per energy type. CSV mapping wizard (/import/wizard): upload an arbitrary CSV, map columns → meters/roles, dry-run preview, then commit as a revertible import_batch (the /import page lists batches with one-click revert). The instant_rate mode is normalized (InstantRateNormalizer: rate integrated over time, trapezoidal). Remaining refinement: full de-DE UI-string localization (data parsing is already de-DE) — noted at its commit. Set MeterVault__SeedReferenceData=true (compose: METERVAULT_SEED=true) for a one-command populated demo.
Source of truth
docs/SDD.md is the authoritative spec and build brief — read it before implementing anything. Key protocol from §0 that governs all work here:
- Build strictly in milestone order (§12, M0→M7). Each milestone is independently runnable and testable; do not start Mn+1 until Mn's tests pass.
- The four CSVs in
sampledata/are golden fixtures. Every parsing / consumption / cost rule must reconcile against them (§13). If a computed number disagrees with the spreadsheet, the spreadsheet wins unless the discrepancy is a deliberately documented correctness fix. - When a design decision is ambiguous, check §14 (open questions): if listed, take the stated default and flag it; if not listed, ask before guessing.
- Keep the domain layer free of infrastructure concerns (the domain model and DB schema are UI-agnostic by design).
Committed tech stack (do not re-litigate; see SDD §4.1)
.NET (current LTS — .NET 10, .NET 8 acceptable), C# · ASP.NET Core + Blazor Server · MudBlazor components · ApexCharts (Blazor-ApexCharts) · MQTTnet · PostgreSQL + TimescaleDB · EF Core (Npgsql) for schema/CRUD + Dapper for hot-path time-series reads · BackgroundService hosted services for ingestion/aggregation · xUnit + Testcontainers (Timescale image) · Docker Compose + GHCR.
Project layout
/src/Core domain entities + enums; pure Normalization engine (mode strategies,
expression evaluator); Parsing (German dialect); Costing (TariffResolver)
/src/Infrastructure MeterVaultDbContext + migrations (relational + raw-SQL Timescale);
Import (CsvImporter, profiles, ImportService), Ingestion (MQTT/HA workers,
IngestionService), Normalization service, Costing/Dashboard/Backup services
/src/App ASP.NET Core host: Blazor Server UI (Components/), REST API (Api/), hosted
workers, Program.cs (Serilog, migrate+seed on startup, /healthz)
/tests/Core.Tests unit (no Docker): parsers, normalizers, swap→12, tariff resolver
/tests/Integration.Tests Testcontainers (Timescale): reconciliation vs the 4 fixtures,
import commit/revert, ingestion, cost, CAgg refresh, API, export, render
/deploy Dockerfile, docker-compose.yml (app + timescaledb), build-and-push.ps1, unraid-template.xml
Central package versions live in Directory.Packages.props; shared build/style in
Directory.Build.props + .editorconfig. Snake_case table/column mapping via
UseSnakeCaseNamingConvention. EF migrations are exempt from code-style enforcement (see .editorconfig).
Commands
dotnet build # build the solution
dotnet test # all tests (Integration.Tests needs Docker for Testcontainers)
dotnet test tests/Core.Tests # unit tests only (no Docker needed)
dotnet test tests/Integration.Tests --filter "FullyQualifiedName~Reconciliation" # one class/area
dotnet ef migrations add <Name> -p src/Infrastructure -s src/App -o Persistence/Migrations
dotnet run --project src/App # run app + workers locally (needs a Timescale DB)
docker compose -f deploy/docker-compose.yml up # app + TimescaleDB together
Timescale-in-EF gotchas (already handled — follow the pattern): hypertable/CAgg DDL lives in
raw-SQL migrations; continuous-aggregate creation + policies use migrationBuilder.Sql(..., suppressTransaction: true), one statement each; CAgg policy end_offset must be ≥ one bucket. Tests
pause the compression job (historical fixture data would otherwise deadlock imports).
Core architecture (the part that spans multiple files)
Data pipeline — one direction, layered (SDD §4.2, §5, §7):
sources (Tasmota/HA/MQTT/manual/CSV)
→ Ingestion workers write raw `reading` rows (immutable audit truth)
→ Normalization derives append-only `consumption` (deltas in base unit)
→ TimescaleDB continuous aggregates roll consumption to hourly/daily/monthly/yearly
→ Cost engine joins aggregates with time-ranged `tariff`
→ Blazor dashboard + REST API read aggregates + cost views
Invariants that shape everything:
- Raw
readingis immutable audit truth. Everything derived (consumption, cost, balances, forecasts) is computed on top and must be reproducible. Never mutate readings to fix a derived number. - Dashboards and charts read aggregates only — never scan
reading. This is what makes 1000 meters × 50 years feasible (§5.5). Raw is kept for a bounded window (default 3y);consumption+ aggregates are the long-term source of truth. meter.mode(measurement mode) is the central abstraction for how raw readings become consumption (SDD §5.2):cumulative_counter,generation_counter,runtime_counter(Δhours × rate),consumable_balance(tank: deliveries − usage + forecast),direct_delta,instant_rate,virtual(expression over other meters). New ingestion/normalization logic dispatches on mode.- Nothing domain-specific is hardcoded. Energy types are data. Cost categories are decoupled from energy types (Heizung may be oil today, heat-pump tomorrow). PV self-consumption/savings/net are virtual meters with user-defined expressions, not special-cased code. Tariffs are time-ranged (price history), scoped global / per-type / per-meter.
Timescale vs EF split (SDD §5.3): EF Core migrations own the relational tables. Timescale-specific DDL — create_hypertable, compression policies, continuous aggregates, retention — is not expressible via EF's model builder and must live in raw-SQL migrations. reading and consumption are hypertables.
Time & DST (SDD §10): store UTC everywhere; bucket and display in the instance timezone (default Europe/Berlin). "Daily cost" boundaries are local-midnight — use time_bucket(..., 'Europe/Berlin').
Secrets (SDD §6.4): broker/HA tokens are never stored in DB plaintext. Two forms, chosen per connector in the admin UI: a reference (token_env/password_env naming an env var or Docker secret path) resolved at runtime, or encrypted at rest (token_enc/password_enc) via SecretProtector over the ASP.NET Core data-protection key ring. Exactly one survives a save; EndpointSecret.Resolve is the single resolution path (encrypted wins). The key ring lives outside the app directory (MeterVault__DataProtectionKeyPath, default /var/lib/metervault/keys) because the LXC updater republishes /opt/metervault. ExportService drops *_enc values — they are bound to the originating key ring.
Reference-data behaviours the code must reproduce (from sampledata/)
These CSVs are the German-dialect Energiebilanz spreadsheet export and define the minimum feature bar (SDD §2, Appendix A). When writing the importer or normalization, honour:
- German number dialect: decimal comma (
180,8244706), thousands dot (2.940,19), trailing-€currency (120,00 €), unit suffixes on values (411kWh,49cm,2287L) — strip and validate. - Two date formats:
Monat YYYY(German month names, monthly tables) andDD.MM.YYYY(event rows). - Skip inline summary rows (
Total,Heute,Seitbeginn Tage,Seit YYYY) and all-zero future placeholder rows (e.g. Dec 2026) — do not ingest them. Negatives are valid (savings, grid balance). - Water register swaps mid-series (…861 → 2 → 15): consumption must stay continuous across the boundary via a
meter_swapevent. - Electricity has 5 meters (Haus, Netz, Auto, Solar 1, Solar 2) plus derived columns. Verified relations to reproduce:
Netz Einsparung = Haus − Netz,Ersparnis = Netz Einsparung × €/kWh,Kosten = Verbrauchskosten − Ersparnis— but implement these as user-definable virtual-meter expressions, not hardcoded formulas. - Heating oil is the versatility stress test: a consumable/tank model where consumption is derivable two ways — tank-level Δ, or burner runtime × rate (rate
fixedfrom nozzle spec, orempirical= Δlevel ÷ Δhours). Early rows (1997–2004) carry deliveries only (no burner hours yet). Includes cm→litre dipstick calibration and forecast-to-empty.
Git